Sonew IP65

Sonew IP65 RFID 리더기 실외용 Wiegand 도어 접근 제어 패널 사용 설명서

모델 : IP65

1. 서론

This manual provides detailed instructions for the installation, operation, and maintenance of the Sonew IP65 RFID Reader Outdoor Wiegand Door Access Control Panel. This device is designed for non-contact induction card access management, offering high user capacity, ease of operation, and stable performance, making it suitable for various access control applications in intelligent communities, offices, and industrial settings.

2. 안전 정보

  • 모든 배선 작업은 자격을 갖춘 전문가가 수행하고 지역 전기 규정을 준수해야 합니다.
  • Disconnect power before performing any installation, wiring, or maintenance procedures.
  • 지정된 작동 범위를 벗어난 극한 온도나 부식성 환경에 기기를 노출시키지 마십시오.
  • 지정된 전원 공급 장치(DC 12V)만 사용하십시오.
  • 기기를 강한 전자기파 간섭으로부터 멀리하십시오.

3. 패키지 내용

패키지에 모든 품목이 들어 있는지 확인하세요.

  • 1 x Sonew IP65 Access Control Panel
  • 10 x Access Cards (Blue Key Fobs)
  • 1 x Access Management Card (Orange Key Fob)
  • 1 x 사용자 설명서
Sonew IP65 RFID Reader with 10 blue key fobs and one orange management card
Image: The Sonew IP65 RFID Reader shown alongside ten blue key fobs for user access and one orange key fob designated as the management card.

4. 사양

사양
모델IP65 metal access controller
검증 방법RFID card / Password / RFID card + Password
사용자 용량1000명의 사용자
카드 종류Mifare one or EM card
작업 볼륨tage직류 12V
작업 전류<100mA (Access Control Unit Only)
환경 온도-20°C ~ 60°C
카드 판독 거리3~15cm
문 열림 시간0~99초(조정 가능)
갠드 인터페이스Wiegand 26 출력/입력
Access Control InterfacesElectronic Lock, Door Sensor, Exit Button, Alarm, Doorbell
재료Metal shell, Zinc alloy
치수(길이 x 너비 x 높이)약 0.39 x 0.39 x 0.39인치
무게약 13.4온스(0.84파운드)
Sonew IP65 RFID Reader installed outdoors in rainy conditions
Image: The IP65-rated access control panel is shown installed outdoors, demonstrating its waterproof capabilities in rainy conditions.

5. 설정 및 설치

5.1. 장치 장착

  1. Securely fix the mounting bracket to the desired installation surface.
  2. Hang the access control unit onto the fixed bracket.

5.2. 배선도

The access control machine's output signal is a relay signal, capable of driving electric locks, automatic doors, turnstiles, and other equipment. Refer to the diagram below for typical wiring connections. For specific wiring methods or complex setups, please consult a qualified technician or supplier.

Wiring diagram for Sonew IP65 RFID Reader showing connections for power, lock, exit button, and Wiegand interface.
Image: Detailed wiring diagram illustrating connections for DC 12V power (Red/Black), electric lock (Brown/Blue/Grey), exit button (Yellow/Push), and Wiegand 26 interface (Green/White).
뒤쪽에 view of the Sonew IP65 RFID Reader showing the wiring terminal block and cable entry.
Image: The rear panel of the access control unit, displaying the terminal block for wiring connections and the cable entry point. The label D8L01833 is visible.

5.3. Setting Unlock Time

The unlock time can be adjusted using the S2 jumper cap on the circuit board:

  • Insert the S2 jumper cap into the '1S' terminal for a 1-second relay activation (factory default).
  • Insert the S2 jumper cap into the '5S' terminal for a 5-second relay activation.

6. 사용 설명서

6.1. Audio-Visual Indicators

작업 상태표시등부저
대기Red light slow flash없음
Add Card Mode녹색 불빛이 빠르게 깜빡입니다.없음
Read Invalid CardRed light slow flash삐-삐-삐
Delete Card Mode빨간불 빠른 플래시없음

6.2. User Management with Management Card

Each machine is pre-configured with a unique management card at the factory. This card is specific to its machine and not interchangeable.

Hand holding a blue RFID key fob near the Sonew IP65 RFID Reader
Image: A user presenting a blue RFID key fob to the Sonew IP65 RFID Reader for access.

6.2.1. Adding User Cards

  1. Ensure the device is in standby mode.
  2. 스와이프 경영카드. The green indicator light will flash rapidly.
  3. 스와이프 User Card(s) you wish to add. The device will emit a 'beep' sound after each successful card addition. You can swipe multiple user cards consecutively.
  4. 스와이프 경영카드 again to exit the add card mode.

6.2.2. Deleting User Cards

  1. Ensure the device is in standby mode.
  2. 스와이프 경영카드. The red indicator light will flash rapidly.
  3. 스와이프 User Card(s) you wish to delete. The device will emit a 'beep' sound after each successful card deletion. You can swipe multiple user cards consecutively.
  4. 스와이프 경영카드 again to exit the delete card mode.

6.2.3. Deleting All Users

  1. 전원 끄기 장치.
  2. Remove the metal back cover. Locate the DEL jumper cap on the circuit board and set it to the '2S' terminal.
  3. 전원 켜기 the machine again. It will continuously beep.
  4. 배치하다 경영카드 on the card reading area for approximately 5 seconds. After a long beep, the machine will continuously beep again, indicating that all user data has been cleared.
  5. 전원 끄기 the device. Reset the DEL jumper cap back to the '1S' terminal.
  6. 전원 켜기 the device. The operation to delete all users is complete.

6.3. Setting/Resetting Management Card

If the management card is lost or needs to be reset, follow these steps:

  1. 전원 끄기 장치.
  2. Short-circuit the 열려 있는 wire (brown) of the 8P terminal block with the 접지 wire (black).
  3. 전원 켜기 the device. After three long beeps, the green light will flash rapidly.
  4. Swipe any 빈 카드. This blank card will now be set as the new Management Card. The machine's red light will flash and the buzzer will continuously beep.
  5. 전원 끄기 the device. Disconnect the OPEN and GND wires.
  6. 전원 켜기 the device again. The machine will enter normal working state, and the management card setup is complete.

7. 고급 기능

7.1. MOD Function

  • MOD Status '1' (Factory Default): If no operation is performed within 3 minutes while in card adding state, the system automatically exits this state.
  • MOD Status '2': The system will not automatically exit the card adding state. It must be exited by swiping the Management Card or by powering off and restarting the device.
  • When in card adding state (MOD Status '2'), swiping any card (except the management card) will output an unlock signal, and the card will be automatically saved. This function is useful for temporary machine replacements or other special scenarios.

7.2. Data Copy Function

This function allows user data to be exported from one access control machine (Machine A) to another (Machine B) using the PROG pin (4P). Data on Machine A will not be deleted.

  1. Connect the PROG pins of Machine A and Machine B using a data cable.
  2. Short-circuit the D0 (green) and GND (black) wires of Machine B.
  3. Power on Machine B (Machine A does not need to be powered on). At this point, the red lights of both A and B will flash slowly.
  4. Place Machine B's 경영카드 on Machine B's card reading area for approximately 5 seconds. Both A and B will emit three long beeps, A's red light will flash rapidly, and B's green light will flash rapidly.
  5. After approximately 30 seconds, A will emit one long beep, and B will continuously beep, indicating successful data copy.
  6. Disconnect the data cable and the D0 and GND wires from Machine B. The data copy operation is complete.

8. 유지관리

  • Regularly clean the surface of the access control panel with a soft, dry cloth. Avoid abrasive cleaners or solvents.
  • 배선 연결부는 주기적으로 점검하여 안전하게 연결되어 있고 부식이 없는지 확인하십시오.
  • Ensure the device is protected from direct impact or physical damage.

9. 문제 해결

  • 장치가 켜지지 않음: Check the DC 12V power supply connection and ensure it is providing adequate power.
  • 카드가 읽히지 않고 있습니다: Ensure the card type (Mifare one or EM) is compatible. Verify the card reading distance. Clean the card reading area.
  • 문이 잠금 해제되지 않음: Check the electric lock wiring. Verify the unlock time setting. Ensure the correct user card or password is being used.
  • Management card lost/not working: Follow the steps in Section 6.3 to reset or set a new management card.
  • All users deleted accidentally: User data cannot be recovered once deleted. Re-add users as necessary.

10. 보증 및 지원

For warranty information, technical support, or service inquiries, please refer to the product's purchase documentation or contact your vendor. Keep your purchase receipt for warranty claims.

© 2025 Sonew. 모든 권리 보유.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.