DANOPLUS KIB-73

DANOPLUS Honey Moisture Refractometer with ATC (Model KIB-73) User Manual

Model: KIB-73

1. 서론

The DANOPLUS Honey Moisture Refractometer is a precision optical instrument designed for measuring the sugar content (Brix), Baume, and water concentration in honey, jelly, jam, and syrup. Equipped with Automatic Temperature Compensation (ATC), it provides accurate and reliable readings across various temperatures. This manual provides detailed instructions for the proper use, calibration, and maintenance of your refractometer.

DANOPLUS Honey Moisture Refractometer

Image: The DANOPLUS Honey Moisture Refractometer, a handheld device for measuring sugar and water content in honey and other high-sugar liquids.

2. 제품 구성품

Your DANOPLUS Refractometer package includes the following items:

  • Refractometer unit with Automatic Temperature Compensation (ATC)
  • 보호용 운반 케이스
  • Calibration oil
  • Polished glass reference block
  • Pipettes for samp르 신청
  • Mini screwdriver for calibration
  • 청소용 천
  • 사용 설명서
Refractometer Kit Contents

Image: The complete refractometer kit, including the device, carrying case, calibration tools, and accessories.

Parts of the Refractometer

Labeled Parts of the Refractometer

Image: Diagram showing the key components of the refractometer, including the Daylight Plate, Calibration Screw, Rubber Grip, Focus Adjustment, and Eyepiece.

  1. Daylight Plate: Covers the prism and holds the samp르.
  2. 교정 나사: Used to adjust the zero line during calibration.
  3. 고무 그립: Provides a secure and comfortable hold.
  4. 초점 조정: Rotates to bring the scale into clear focus.
  5. 접안 렌즈: Where the user looks to read the scale.

3. 설정 및 교정

Before first use, or if you suspect inaccurate readings, calibrate the refractometer. Calibration should be performed at room temperature (approximately 20°C / 68°F).

초기 설정

  1. Ensure the prism and daylight plate are clean and dry. Use the provided cleaning cloth.
  2. Point the daylight plate towards a bright light source (e.g., daylight or a light bulb).
  3. Look through the eyepiece and adjust the focus adjustment ring until the scale is clear.

교정 절차

  1. Open the daylight plate.
  2. Place 2-3 drops of the provided calibration oil onto the main prism.
  3. Close the daylight plate gently, ensuring the oil spreads evenly without air bubbles.
  4. 약 30초 정도 기다려 주세요.ample to equalize to the instrument's temperature.
  5. Point the daylight plate towards a bright light source and look through the eyepiece.
  6. Observe the boundary line between the blue and white fields. For honey refractometers, this line should align with the 78.8% Brix mark (or the specific calibration point indicated for your model, often near the middle of the scale for calibration oil).
  7. If the line is not at the correct mark, use the mini screwdriver to turn the calibration screw until the boundary line aligns precisely with the specified calibration point.
  8. After calibration, clean the prism and daylight plate thoroughly with a damp 천으로 닦아내고 부드럽고 보푸라기가 없는 천으로 말리세요.
굴절계 보정

Image: A screwdriver being used to adjust the calibration screw on the refractometer, aligning the boundary line for accurate measurements.

4. 사용 설명서

Follow these steps to take accurate measurements with your refractometer:

  1. Ensure the prism and daylight plate are clean and dry.
  2. Open the daylight plate.
  3. Using a pipette, place 2-3 drops of the sample (e.g., honey, jelly, syrup) onto the main prism.
  4. Close the daylight plate gently, ensuring the sample spreads evenly across the entire surface of the prism without air bubbles.
  5. 약 30초 정도 기다려 주세요.ample to equalize to the instrument's temperature. This is crucial for accurate readings, especially with ATC.
  6. Point the daylight plate towards a bright light source (do not look directly at the sun).
  7. Look through the eyepiece and adjust the focus adjustment ring until the scale is clear.
  8. Read the value where the boundary line between the blue and white fields crosses the scale. The scale typically shows Brix%, Baume, and Water% for honey.
  9. After each measurement, clean the prism and daylight plate thoroughly with a damp cloth and dry with a soft, lint-free cloth. Failure to clean properly can lead to inaccurate readings and damage to the prism.
Applying Honey Sample to Refractometer

Image: A hand using a pipette to apply a honey sample onto the prism of the refractometer for measurement.

Understanding the Scale

The refractometer features a clear, easy-to-read scale with distinct measurements for Brix, Baume, and Water content. The boundary line indicates the measurement value.

Refractometer Measurement Scale

이미지: 클로즈업 view of the refractometer's internal scale, showing markings for Brix%, Water%, and Baume at 20°C.

  • Brix (%): Measures the total soluble solids, primarily sugar content.
  • Baume (Be'): Another scale for measuring sugar concentration, often used for honey.
  • Water (%): Indicates the water content in the sample, critical for honey quality and storage.

5. 유지관리 및 관리

Proper maintenance ensures the longevity and accuracy of your refractometer.

  • 청소: Always clean the prism and daylight plate immediately after use. Use a soft, damp cloth (preferably lint-free) to wipe off any residue. Dry thoroughly with a clean, soft cloth. Do not rinse the entire instrument under water.
  • 저장: Store the refractometer in its protective carrying case when not in use. Keep it in a dry, cool place, away from direct sunlight and extreme temperatures.
  • 손질: Handle the instrument with care. Avoid dropping it or subjecting it to strong impacts, as this can damage the optical components.
  • Avoid Corrosive Substances: Do not use corrosive or abrasive cleaning agents on any part of the refractometer.

6. 문제 해결

If you encounter issues with your refractometer, refer to the following common problems and solutions:

문제가능한 원인해결책
부정확한 판독
  • 부적절한 보정
  • Prism or daylight plate is dirty
  • Sample temperature not equalized
  • s가 부족합니다amp음량
  • Recalibrate the instrument (see Section 3).
  • Clean the prism and daylight plate thoroughly.
  • 허용ample to sit on the prism for 30 seconds before reading.
  • Ensure 2-3 drops of sample cover the entire prism surface.
Blurry scale or field of view
  • Eyepiece out of focus
  • Eyepiece or prism dirty
  • Adjust the focus adjustment ring on the eyepiece.
  • Clean the eyepiece lens and prism.
Boundary line not sharp
  • Insufficient light source
  • 공기 방울ample
  • Use a brighter, diffused light source.
  • Reapply sample, ensuring no air bubbles are trapped.

If problems persist, contact DANOPLUS customer support for further assistance.

7. 사양

특징세부 사항
측정 범위Brix: 58-90%, Baume: 38-43 Be', Water: 12-27%
정확성Brix: ±0.5%, Baume: ±0.25 Be', Water: ±0.5%
자동 온도 보상 (ATC)
품목 모델 번호KIB-73
품목 무게11.4 온스
패키지 크기8.43 x 3.58 x 2.24 인치
필요한 배터리아니요

8. 보증 및 지원

For warranty information or technical support, please contact DANOPLUS customer service. Keep your purchase receipt as proof of purchase.

제조업체: 다노플러스

연락하다: Refer to the DANOPLUS official website or your retailer for current contact information.

© 2024 DANOPLUS. All rights reserved.