1. 제품 오버view

The Elitech LogEt 8 BLE is a Bluetooth wireless multi-use PDF data logger designed for monitoring temperature in various life science applications. It features a USB port for direct data download and PDF report generation, and Bluetooth connectivity for remote management via the Elitech App.

주요 특징:

  • 무선 블루투스 기술: Enables one-click pairing and remote programming/management via the Elitech App within meters.
  • 넓은 온도 측정 범위: -22℉ to 158℉ (-30℃ to 70℃) with an accuracy of ±0.9℉ (±0.5℃).
  • 모바일 앱 호환성: Free Elitech App for iOS and Android devices facilitates remote logger management and cold chain monitoring.
  • Multi-use Capability: Designed for repeated use over approximately 2 years under room temperature conditions.
  • 자동 데이터 동기화: Automatically uploads all recorded data to your account when connected to the Elitech APP.
  • High Recording Capacity: Stores up to 16,000 recording points.
앞쪽 view of Elitech LogEt 8 BLE data logger with labeled components: USB Port, LCD Screen, START Button, STOP Button, Embedded Temperature Sensor.

그림 1: 전면 view of the LogEt 8 BLE data logger with labeled components.

2. 패키지 내용

상자를 풀 때 모든 품목이 패키지에 들어 있는지 확인하세요.

  • 1 x LogEt 8 BLE Data Logger
  • 1 x 사용자 설명서
  • 1 x 교정 인증서
Image showing the Elitech LogEt 8 BLE data logger package contents, including the data logger, user manual, and calibration certificate.

Figure 2: Contents included in the LogEt 8 BLE package.

3. 장치 구성 요소

Familiarize yourself with the main components of the LogEt 8 BLE data logger:

  • USB 포트: Located at the top, protected by a removable cap. Used for direct connection to a computer for data download and configuration.
  • LCD 화면: Displays current temperature, alarm status, recording status, and battery level.
  • 시작 버튼: 데이터 기록을 시작합니다.
  • 정지 버튼: Halts data recording.
  • Embedded Temperature Sensor: Internal sensor for accurate temperature measurement.

4. 설정

4.1 초기 설정

  1. 장치 포장 풀기: Carefully remove the LogEt 8 BLE from its packaging.
  2. 손상 여부 검사: Check the device for any visible damage. If damaged, contact customer support.
  3. 배터리 활성화: The device comes with a pre-installed lithium metal battery. No initial activation is typically required.

4.2 Software Installation (Elitech App)

To fully utilize the LogEt 8 BLE's features, download the Elitech App on your mobile device:

  • 검색 "Elitech" in the Apple App Store (for iOS) or Google Play Store (for Android).
  • Download and install the official Elitech App.
  • 계정을 만들거나 이미 계정이 있으면 로그인하세요.

4.3 블루투스를 통한 연결

앱이 설치되면:

  1. 모바일 장치에서 Bluetooth가 활성화되어 있는지 확인하십시오.
  2. Open the Elitech App.
  3. The app will scan for nearby Elitech data loggers. Select your LogEt 8 BLE from the list to pair.
  4. Follow any on-screen prompts for one-click pairing.

4.4 Programming the Logger

Before starting a recording, configure the logger's parameters using the Elitech App or by connecting directly to a computer via USB:

  • Via Elitech App: Within the app, navigate to the settings for your connected LogEt 8 BLE. You can set parameters such as sampling interval, alarm thresholds, start delay, and recording duration.
  • Via USB (PC Software): Remove the protective cap to expose the USB port. Connect the logger to a computer. Use the Elitech data management software (downloadable from the Elitech website) to configure settings.
옆 view of Elitech LogEt 8 BLE data logger showing a default parameters sticker with alarm settings, start-up delay, record day, and data samp링 간격.

Figure 3: Default parameters sticker on the side of the device.

5. 사용 설명서

5.1 녹음 시작

To begin data logging:

  • 를 누르고 계세요 시작 button for approximately 3 seconds until the "REC" indicator appears on the LCD screen.
  • If a start delay was configured, the logger will begin recording after the specified delay.

5.2 녹화 중지

To end data logging:

  • 를 누르고 계세요 멈추다 button for approximately 3 seconds until the "END" indicator appears on the LCD screen.
  • Alternatively, connect the logger to the Elitech App or PC software and select the option to stop recording.

5.3 데이터 다운로드 및 보고서 생성

After recording, data can be retrieved and analyzed:

  • USB를 통해: Remove the USB cap and plug the logger into a computer's USB port. The logger will automatically generate a PDF report and a CSV data file. 이것들 files can be accessed directly from the logger's virtual drive.
  • Via Elitech App: Connect the logger to the Elitech App via Bluetooth. The app will automatically sync and upload all data to your account. You can then view graphs, export data, or generate reports directly from the app.
Elitech LogEt 8 BLE data logger with USB port exposed, displaying temperature in Fahrenheit, and indicating temperature range (-30°C/-22°F to 70°C/158°F) and 16000 points record capacity.

Figure 4: LogEt 8 BLE with USB port exposed and key specifications.

6. 유지관리

6.1 배터리 정보

The LogEt 8 BLE is powered by a non-rechargeable lithium metal battery. The battery is designed to last for approximately 2 years under normal operating conditions. The battery is contained within the equipment and is not user-serviceable. Attempting to replace the battery may damage the device and void the warranty.

6.2 청소

장치를 청소하려면:

  • 부드럽고 마른 천으로 외부를 닦습니다.
  • 연마성 세척제, 용제를 사용하거나 기기를 물에 담그지 마십시오.

6.3 보관

When not in use, store the data logger in a cool, dry place, away from direct sunlight and extreme temperatures.

7. 문제 해결

If you encounter issues with your LogEt 8 BLE, refer to the following common problems and solutions:

  • 장치가 켜지지 않음: Check battery level on the LCD. If the battery is depleted, the device may need replacement as the battery is not user-serviceable.
  • 블루투스로 연결할 수 없습니다: Ensure Bluetooth is enabled on your mobile device and the Elitech App is open. Make sure the logger is within range. Restart both the logger and your mobile device.
  • 기록된 데이터가 없습니다. Verify that recording was properly started (check for "REC" on LCD). Ensure the logger's memory is not full.
  • PDF report not generated: Ensure the logger is connected to a computer's USB port correctly. Try a different USB port or computer. Ensure the USB cap is fully removed.
  • 부정확한 판독값: Ensure the logger's sensor is not obstructed and is placed in an environment suitable for its operating range.

추가적인 도움이 필요하시면 Elitech 고객 지원팀에 문의하십시오.

8. 사양

특징사양
모델 번호LogEt 8 BLE
온도 측정 범위-30 ℃ ~ 70 ℃ (-22 ℉ ~ 158 ℉)
온도 정확도±0.5℃(±0.9℉)
기록 용량16,000점
연결성블루투스, USB
전원1 x Lithium Metal battery (included, non-replaceable)
특징알람 기능
품목 무게60g
제품 치수9.98 x 4.6 x 1.88cm(3.93 x 1.81 x 0.74인치)
원산지미국
하드웨어 인터페이스 유형USB

9. 보증 및 지원

9.1 보증 정보

Elitech products typically come with a limited warranty covering manufacturing defects. Please refer to the warranty card included in your package or visit the official Elitech website for specific warranty terms and conditions applicable to the LogEt 8 BLE.

9.2 고객 지원

For technical support, troubleshooting assistance, or warranty claims, please contact Elitech customer service:

  • Web대지: 방문하다 www.엘리테쿠스.com 자주 묻는 질문(FAQ), 소프트웨어 다운로드 및 연락처 정보는 여기를 참조하십시오.
  • 이메일/전화: Refer to the Elitech web최신 연락처 정보는 웹사이트 또는 제품 포장에서 확인하실 수 있습니다.

© 2024 Elitech. 모든 권리 보유.