ADC Prosphyg 760
ADC Prosphyg 760 포켓형 아네로이드 혈압계 사용 설명서
Model: Prosphyg 760
브랜드: ADC
소개
This manual provides comprehensive instructions for the proper use, care, and maintenance of your ADC Prosphyg 760 Pocket Aneroid Sphygmomanometer. Please read this manual thoroughly before using the device to ensure accurate readings and safe operation. This device is designed for professional and personal use in measuring blood pressure.
안전 정보
Always follow basic safety precautions when using medical devices. Failure to do so may result in inaccurate readings or injury.
- 기기를 직접 수리하거나 개조하지 마십시오. 모든 서비스는 자격을 갖춘 전문가에게 맡기십시오.
- 기기를 어린이의 손이 닿지 않는 곳에 보관하세요.
- 극심한 온도 변화, 높은 습도 및 직사광선을 피하십시오.
- Do not immerse the cuff or gauge in water.
- Consult a healthcare professional for interpretation of blood pressure readings. This device is for measurement only.
구성 요소
Your ADC Prosphyg 760 Sphygmomanometer typically includes the following components:
- Aneroid Gauge: The dial that displays blood pressure readings.
- Inflation Bulb: Used to inflate the cuff.
- Air Release Valve: Controls the deflation rate of the cuff.
- Adcuff Nylon Blood Pressure Cuff: The fabric cuff that wraps around the arm.
- Inflation Bag (Bladder): Inside the cuff, inflates to compress the artery.
- Tubing: Connects the gauge, bulb, and cuff.

Image showing the typical components of an aneroid sphygmomanometer, including the gauge, cuff, and inflation bulb. Please note: The provided image is a placeholder and does not depict the actual product.
설정
Before taking a measurement, ensure the device is properly assembled and the patient is prepared.
- Cuff Selection: Choose the appropriate cuff size for the patient's arm circumference. The cuff should fit snugly but not too tightly.
- 환자 위치: 환자가 등을 기대고 발을 바닥에 평평하게 놓은 채 편안하게 앉도록 합니다. 측정할 팔은 심장 높이에 위치하도록 지지해야 합니다.
- 커프 배치: Wrap the cuff around the bare upper arm, approximately 1 inch (2-3 cm) above the elbow crease. Ensure the artery marker on the cuff aligns with the brachial artery.
- 구성 요소 연결: Ensure the tubing securely connects the cuff to the aneroid gauge and inflation bulb.
작동 지침
Follow these steps to accurately measure blood pressure using your ADC Prosphyg 760.
- 공기 배출 밸브를 닫으십시오: Turn the air release valve (usually a screw valve on the inflation bulb) clockwise until it is fully closed. Do not overtighten.
- 커프 팽창시키기: 혈압계 바늘의 팽창 펌프를 눌러 커프를 빠르게 팽창시켜 환자의 평소 수축기 혈압보다 약 20~30mmHg 높아지거나 요골 맥박이 더 이상 촉지되지 않을 때까지 압력을 가합니다.
- Deflate Cuff Slowly: Slowly open the air release valve by turning it counter-clockwise. The needle on the gauge should drop at a rate of 2-3 mmHg per second.
- Listen for Korotkoff Sounds (if using stethoscope):
- 수축기 압력: Note the reading on the gauge when you hear the first clear, tapping sound (Korotkoff Phase I).
- 이완기 압력: Note the reading on the gauge when the sounds disappear completely (Korotkoff Phase V).
- 기록된 측정값: Record both systolic and diastolic pressures.
- 완전히 수축: Once readings are taken, fully open the air release valve to deflate the cuff completely.
- Wait Between Readings: If taking multiple readings, wait at least 1-2 minutes between measurements.
메모: For accurate blood pressure measurement, it is recommended to use this device in conjunction with a stethoscope to auscultate Korotkoff sounds.
유지 보수 및 관리
Proper care will extend the life and accuracy of your sphygmomanometer.
- 청소:
- 동: The nylon cuff can be cleaned with a mild detergent and water. Allow to air dry completely before storage. Do not machine wash or dry.
- Gauge and Bulb: 부드러운 천으로 닦으십시오. damp cloth. Do not use abrasive cleaners or immerse in liquid.
- 저장: Store the device in its carrying case (if provided) in a cool, dry place, away from direct sunlight and extreme temperatures.
- 구경 측정: Aneroid sphygmomanometers should be checked for accuracy and recalibrated annually, or more frequently if dropped or mishandled. Contact ADC customer service or a certified technician for calibration services.
문제 해결
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| 커프가 팽창하지 않거나 팽창 속도가 느립니다. | Air leak in cuff, tubing, or bulb; valve not closed. | Check all connections for tightness. Ensure air release valve is fully closed. Inspect cuff and tubing for cracks or holes. |
| Gauge needle does not return to zero. | 측정기가 교정되지 않았거나 손상되었습니다. | Do not use. Contact ADC for calibration or repair. |
| 측정값이 일관성이 없거나 부정확합니다. | Improper cuff size or placement; patient movement; rapid deflation; gauge out of calibration. | Ensure correct cuff size and proper placement. Instruct patient to remain still. Deflate cuff at 2-3 mmHg/sec. Check calibration. |
명세서
- 모델: Prosphyg 760
- 유형: 포켓 아네로이드 혈압계
- 커프 유형: Adcuff Nylon Blood Pressure Cuff (Adult size, Black)
- 측정 방법: Auscultatory (requires stethoscope for Korotkoff sounds)
- 측정 범위: Typically 0-300 mmHg
- 정확성: Certified to meet or exceed ANSI/AAMI SP10 standards (when calibrated)
보증 및 지원
ADC products are manufactured to high standards and are backed by a limited warranty. For specific warranty details, please refer to the warranty card included with your product or visit the official ADC web대지.
For technical support, calibration services, or replacement parts, please contact ADC customer service:
- Web대지: www.adctoday.com (This is a generic placeholder, user should check actual ADC web대지)
- 핸드폰: 제품 포장을 참조하거나 web연락처 정보는 사이트에서 확인하세요.
- 이메일: 제품 포장을 참조하거나 web연락처 이메일 사이트입니다.
When contacting support, please have your model number (Prosphyg 760) and purchase date available.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.