Renishaw OMP60

레니쇼 OMP60 공작기계 프로브 키트 사용 설명서

Model: OMP60

1. 서론

This manual provides essential information for the safe and effective use of the Renishaw OMP60 Machine Tool Probe Kit. The OMP60 is a compact 3D touch-trigger probe designed for workpiece set-up and inspection on a wide range of medium and large machining centers. It utilizes optical signal transmission for reliable communication. Proper understanding and adherence to these instructions will ensure optimal performance and longevity of your Renishaw OMP60 probe.

2. 제품 오버view

The Renishaw OMP60 probe is engineered to enhance manufacturing efficiency by reducing set-up times, minimizing scrap, and lowering fixture costs. Its robust design and optical signal transmission system ensure high accuracy and reliability in demanding industrial environments. The probe is compatible with both legacy and new generation Renishaw optical receivers, facilitating seamless integration into existing machine setups.

주요 특징은 다음과 같습니다.

  • Compact 3D touch-trigger design.
  • Optical signal transmission for reliable data transfer.
  • Suitable for workpiece set-up and inspection.
  • Broad compatibility with Renishaw optical receivers.

3. 안전 정보

Always observe standard safety precautions when working with machine tools and precision equipment. Failure to do so may result in injury or damage to the equipment.

  • Ensure the machine tool is powered off and locked out before installing or removing the probe.
  • Handle the probe with care to prevent damage to its precision components.
  • Only use approved accessories and replacement parts from Renishaw.
  • Refer to your machine tool's operating manual for specific safety guidelines related to probe usage.
  • 현지 규정에 따라 배터리를 폐기하십시오.

4. 패키지 내용

Upon opening your Renishaw OMP60 Machine Tool Probe Kit, verify that all components are present and undamaged. The standard kit typically includes the following items:

Renishaw OMP60 probe kit in its original packaging

Image: The Renishaw OMP60 probe kit as received in its original cardboard packaging, showing the probe unit, a quick-start guide, two AA batteries, and a small toolkit.

Contents of the Renishaw OMP60 probe kit laid out

Image: The individual components of the Renishaw OMP60 probe kit laid out, including the OMP60 probe, a quick-start guide, two Duracell AA alkaline batteries, and a small plastic bag containing a toolkit (likely styli or adjustment tools).

  • Renishaw OMP60 Probe Unit
  • Quick-start Guide (A-1038-8501)
  • AA Alkaline Batteries (typically 2)
  • OMP60 Toolkit (RMP/OMP60 TOOLKIT A-4038-0208-02)

5. 설정

Follow these general steps for setting up your Renishaw OMP60 probe. For detailed, model-specific instructions, refer to the included Quick-start Guide and the comprehensive Renishaw OMP60 installation manual.

  1. 포장 풀기 및 검사: Carefully remove all components from the packaging. Inspect the probe and accessories for any signs of damage.
  2. 배터리 설치: Access the battery compartment, typically located at the bottom of the probe. Insert the provided AA batteries, ensuring correct polarity. Securely close the compartment.
  3. Stylus Attachment: Select the appropriate stylus for your application. Carefully thread the stylus onto the probe's mounting point. Ensure it is securely fastened but do not overtighten.
  4. 프로브 장착: Mount the OMP60 probe into the machine tool spindle or tool holder. Ensure it is seated correctly and securely clamp편집.
  5. Optical Receiver Setup: Ensure your Renishaw optical receiver (e.g., OMI-2, OMI-2T) is correctly installed and aligned with the probe's optical transmission window. Refer to the receiver's manual for installation and alignment procedures.
  6. Machine Control Integration: Configure your machine tool's CNC control system to recognize and communicate with the OMP60 probe. This typically involves setting up probe cycles and offset registers.
  7. 초기 교정: Perform an initial calibration of the probe using a known reference artifact (e.g., a calibration sphere). This establishes the probe's trigger points and ensures measurement accuracy.
Close-up of the Renishaw OMP60 probe

이미지: 자세한 view of the Renishaw OMP60 probe unit, highlighting the branding, model number, and 'MADE IN UK' inscription. This view shows the main body and the transparent section revealing internal electronics.

맨 위 view of the Renishaw OMP60 probe

이미지: 위에서 아래로 view of the Renishaw OMP60 probe, showing the central stylus mounting point with a hexagonal socket and surrounding adjustment mechanisms.

6. 사용 설명서

The Renishaw OMP60 probe is designed for automated workpiece measurement and inspection cycles within a machine tool environment. Operation is typically controlled via the machine's CNC system.

  1. 프로그램 선택: Select the appropriate probing cycle program on your machine tool's CNC control. These programs are designed for specific measurement tasks, such as workpiece alignment, feature measurement, or tool setting.
  2. 작업물 준비: 공작물이 단단히 고정되었는지 확인하십시오.amped and positioned on the machine table.
  3. Cycle Execution: Initiate the probing cycle from the CNC control. The machine will automatically move the probe to the designated measurement points.
  4. 데이터 해석: The measurement data collected by the OMP60 probe is transmitted to the CNC control, where it can be used to update work offsets, perform in-process inspection, or generate reports.

자세한 프로그래밍 예시는 다음과 같습니다.amples and specific operational sequences, consult the Renishaw OMP60 user manual and your machine tool's programming guide.

Renishaw OMP60 probe showing trigger force adjustment

이미지: 클로즈업 view of the Renishaw OMP60 probe, indicating the 'TRIGGER FORCE' adjustment screw with directional arrows for increasing 또는 감소asing the trigger force. This adjustment allows fine-tuning of the probe's sensitivity.

7. 유지관리

Regular maintenance ensures the continued accuracy and reliability of your Renishaw OMP60 probe.

  • 청소: Periodically clean the probe's exterior, especially the optical transmission window, using a soft, lint-free cloth. Avoid abrasive cleaners or solvents.
  • 스타일러스 점검: Regularly inspect the stylus for wear, damage, or contamination. Replace damaged styli immediately to maintain measurement accuracy.
  • 배터리 교체: Replace batteries when the low battery indicator is displayed or when performance degrades. Always use high-quality alkaline batteries.
  • 저장: When not in use, store the probe in a clean, dry environment, preferably in its original packaging or a protective case.
맨 아래 view of the Renishaw OMP60 probe

Image: A bottom view of the Renishaw OMP60 probe, showing the battery compartment cover with three securing screws and a central access point.

8. 문제 해결

This section addresses common issues you might encounter with the OMP60 probe. For more complex problems, contact Renishaw technical support.

문제가능한 원인해결책
Probe not activating배터리 부족 또는 방전
Incorrect optical receiver alignment
Obstruction of optical path
Machine control error
배터리를 교체하세요
Re-align optical receiver
Clean optical window and ensure clear path
Check CNC program and machine status
부정확한 측정Damaged or worn stylus
프로브가 보정되지 않았습니다.
Contamination on stylus or workpiece
Incorrect trigger force setting
Replace stylus
Perform probe calibration
Clean stylus and workpiece
Adjust trigger force (refer to Section 6 image)
간헐적인 신호 손실약한 배터리
환경 간섭
Partial obstruction of optical path
배터리를 교체하세요
Minimize sources of optical interference
Ensure clear line of sight between probe and receiver

9. 사양

The Renishaw OMP60 is a precision instrument. Key specifications include:

  • 프로브 유형: 3D Touch-Trigger Probe
  • 전염: 광학
  • 전원: AA 배터리
  • 패키지 크기: 약 10 x 8 x 5mm(254 x 203 x 127인치)
  • 제조업체: 레니쇼
  • 원산지: United Kingdom (as indicated on the probe)

For detailed technical specifications, including trigger force ranges, measurement repeatability, and environmental operating conditions, please refer to the official Renishaw OMP60 product data sheet or the full user manual available from Renishaw.

10. 보증 및 지원

The Renishaw OMP60 Machine Tool Probe Kit typically comes with a manufacturer's warranty. Specific warranty terms and conditions are usually provided with the product documentation or can be obtained directly from Renishaw or your authorized distributor. It is recommended to register your product upon purchase to facilitate any warranty claims.

For technical assistance, service, or to inquire about replacement parts, please contact Renishaw customer support or your local Renishaw representative. Contact information can be found on the official Renishaw web사이트 (www.renishaw.co.kr).

© 2023 Renishaw plc. All rights reserved. Information is subject to change without notice.