1. 서론
The CCEI DHG2 Anti-Frost Device is designed to protect your swimming pool's piping system from freezing during cold temperatures, ensuring the longevity of your installation. This device automatically circulates water when temperatures drop, preventing ice formation and potential damage to your pool infrastructure.
주요 특징
- Automated winterization for peace of mind.
- Precise temperature measurement with a CTN probe.
- Easy integration with existing pool electrical systems.
- Digital temperature display for clear monitoring.
- Activates filtration when the temperature falls below a set threshold.
2. 중요 안전 지침
Please read and understand all safety instructions before installing or operating the CCEI DHG2 device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- 설치는 모든 지역 및 국가 전기 규정에 따라 자격을 갖춘 전기 기술자가 수행해야 합니다.
- Always disconnect the main power supply to the pool system before performing any installation, maintenance, or troubleshooting.
- Do not operate the device if it appears damaged or is malfunctioning. Contact qualified service personnel.
- 작동 중에는 어린이와 허가받지 않은 사람이 장치에 접근하지 못하도록 하세요.
- Ensure the device is protected from direct weather exposure unless specifically rated for outdoor use.
3. 패키지 내용
포장을 풀 때 모든 품목이 들어 있고 손상되지 않았는지 확인하세요.
- CCEI DHG2 Anti-Frost Device Control Box
- CTN Temperature Probe
- 사용 설명서 (본 문서)
4. 설정 및 설치
The CCEI DHG2 device is designed for straightforward integration into your pool's electrical system. Proper installation is crucial for optimal performance and safety.
4.1 장치 장착
Select a suitable location for mounting the DHG2 control box. This location should be protected from direct weather exposure (rain, direct sunlight) and easily accessible for operation and maintenance. Use appropriate fasteners to secure the unit to a stable surface.

이미지: 앞면 view of the CCEI DHG2 Anti-Frost Device, showing the digital temperature display and control buttons.
4.2 전기 연결
Connect the DHG2 anti-frost device to your main pool electrical panel. The device typically requires a dedicated power supply. Refer to the detailed wiring diagram provided inside the device cover for specific connection points and ensure all connections are secure and properly insulated. It is recommended to use appropriate conduit for wiring.
The CTN temperature probe must be installed in a location that accurately measures the pool water temperature, typically within the filtration circuit or a dedicated probe well. Ensure the probe is fully immersed in water for accurate readings.

Image: CCEI DHG2 Anti-Frost Device integrated into a swimming pool's filtration system, showing pipe connections.
5. 운영
5.1 초기 전원 켜기
Once installed and wired, switch on the main power supply to the DHG2 device. The digital display will illuminate, showing the current water temperature measured by the CTN probe.
5.2 Setting the Anti-Frost Threshold
The DHG2 allows you to set a specific temperature threshold. When the water temperature falls below this set point, the device will automatically activate the pool's filtration pump to circulate water and prevent freezing.
- Press the 'SET' button on the control panel. The display will show the currently programmed anti-frost activation temperature.
- Use the 'Up' and 'Down' arrow buttons to adjust the desired temperature threshold. A common setting is between 0°C and 3°C (32°F and 37.4°F).
- Press 'SET' again to confirm and save the new setting. The display will then revert to showing the current water temperature.
5.3 강제 순환 모드
The DHG2 may include a forced circulation mode, which can be manually activated. This mode ensures continuous water movement and increases pressure within the pipes, further lowering the freezing point of the water. This can be particularly useful during extreme cold snaps or for specific maintenance procedures.
Refer to the device's specific button layout for activating this mode, which is typically a dedicated button or a combination of existing buttons (e.g., holding an arrow button for a few seconds).
6. 유지관리
Regular maintenance ensures the optimal performance and longevity of your CCEI DHG2 Anti-Frost Device.
- 시각적 검사: Periodically inspect the device, wiring, and connections for any signs of wear, corrosion, or damage.
- 청소: Keep the digital display and control buttons clean and free from dust or debris. Use a soft, dry cloth for cleaning.
- 프로브 점검: Ensure the CTN temperature probe is clean and properly positioned in the water for accurate readings. Remove any buildup that might affect its sensitivity.
- 겨울철 보관(해당되는 경우): If the device is removed for off-season storage, ensure it is stored in a dry, protected environment.
7. 문제 해결
This section provides solutions to common issues you might encounter with your DHG2 device.
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| 장치 전원이 켜지지 않음 | 전원 공급이 없습니다 | Check the circuit breaker and all electrical connections. Ensure the main power to the pool system is on. |
| 잘못된 온도 판독값 | Faulty or dirty probe, or probe not immersed | Clean or replace the CTN temperature probe. Ensure it is correctly installed and fully immersed in water. |
| Pool pump not activating when cold | Temperature above threshold, wiring issue, or pump malfunction | Verify the set temperature threshold. Check wiring connections to the pump. Test the pump independently to ensure it is functional. |
| 디지털 디스플레이에 오류 코드가 표시됩니다. | Internal fault or sensor issue | Consult the specific error code in the full technical manual (if available) or contact CCEI customer support for assistance. |
If problems persist after attempting these solutions, please contact CCEI customer support or a qualified service technician.
8. 기술 사양
Below are the general technical specifications for the CCEI DHG2 Anti-Frost Device:
| 특징 | 세부 사항 |
|---|---|
| 모델 | DHG2 |
| 상표 | 한국정보통신기술협회 |
| 치수(포장) | 18.4 x 18.2 x 17.2cm |
| 무게(포장) | 660그램 |
| 온도 센서 유형 | CTN (Negative Temperature Coefficient) |
| 디스플레이 유형 | 디지털 |
| 주요 기능 | Automatic Anti-Frost Protection for Pool Systems |
참고: 사양은 사전 통지 없이 변경될 수 있습니다.
9. 보증 및 고객 지원
The CCEI DHG2 Anti-Frost Device comes with a standard manufacturer's warranty. Please refer to your purchase documentation or the official CCEI website for specific warranty terms and conditions, including duration and coverage.
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact CCEI customer support through their official website or your local authorized distributor. Ensure you have your product model number (DHG2) and proof of purchase available when contacting support.