ABUS 3632

ABUS 3632 Door Closer TS40 AL Instruction Manual

Model: TS40 AL (3632)

1. 서론

Thank you for choosing the ABUS 3632 Door Closer TS40 AL. This spring-loaded automatic door closer is designed for flush doors, providing reliable and controlled closing. It features three adjustable closing force levels to suit various door weights and closing requirements. This manual provides essential information for safe installation, operation, and maintenance of your door closer.

2. 안전 정보

  • 설치 및 사용 전에 모든 지침을 주의 깊게 읽으십시오.
  • Ensure all fixing materials are securely fastened to prevent injury or damage.
  • Do not attempt to disassemble or modify the door closer. This may void the warranty and pose a safety risk.
  • 작동 및 조정 중에는 움직이는 부품에 손과 손가락이 닿지 않도록 주의하세요.
  • This door closer is intended for a maximum door weight of up to 20 kg. Exceeding this limit may result in improper function or damage.
  • 설치 시에는 항상 적절한 도구를 사용하십시오.

3. 패키지 내용

The ABUS 3632 Door Closer TS40 AL package includes:

  • 1 x ABUS Door Closer TS40 AL unit
  • All necessary fixing materials (screws, etc.)
  • 사용 설명서(본 문서)

4. 제품 사양

모델 번호: 3632
재료: 합금강, 알루미늄
색상:
외부 마감 :
제품 크기(길이 x 너비 x 높이): 13.39" x 3.74" x 1.06"(340mm x 95mm x 27mm)
품목 무게: 0.34kg
설치 유형: 나사로 고정
권장 사용: Commercial, Flush Doors
최대. 문 무게: 최대 20kg
Closing Force Levels: 3 단계 조절 가능
호환성: DIN right / DIN left doors
Technical drawing with dimensions of the ABUS 3632 Door Closer TS40 AL

Figure 1: Technical dimensions of the ABUS 3632 Door Closer. The main body is 180mm long, and the arm is 163mm long.

5. 설정 및 설치

The ABUS 3632 Door Closer TS40 AL is designed for easy screw-in installation on flush doors. It is compatible with both DIN right and DIN left opening doors.

5.1 설치 전

  • Ensure the door is clean and free from obstructions.
  • Verify that the door weight does not exceed 20 kg.
  • Gather necessary tools: drill, screwdriver, measuring tape, pencil.

5.2 설치 단계

  1. Positioning the Closer: Determine the desired mounting position on the door frame or door leaf. The closer can be mounted on the pull side or push side, depending on the door's opening direction (DIN right/left).
  2. Diagram showing two doors, illustrating DIN right and DIN left door opening applications for the closer.

    Figure 2: Illustration of DIN right and DIN left door applications.

  3. 드릴 구멍 표시하기: Use the door closer as a template to mark the screw hole positions on the door or frame. Ensure the closer is level.
  4. 파일럿 홀 드릴링: Drill pilot holes at the marked positions. The size of the drill bit should be slightly smaller than the screws provided.
  5. Attaching the Closer Body: Securely fasten the main body of the door closer to the door or frame using the provided screws.
  6. Attaching the Arm: Attach the arm to the door closer body and to the door frame or door leaf, depending on the mounting configuration. Ensure all connections are tight.
  7. ABUS 3632 Door Closer TS40 AL installed on a light wooden door, showing the main body mounted on the door frame and the arm extending to the door.

    Figure 3: ABUS 3632 Door Closer TS40 AL correctly installed on a door.

  8. 초기 테스트: Open and close the door a few times to ensure smooth operation and proper alignment.

6. 작동 및 조정

The ABUS 3632 Door Closer TS40 AL features a smooth, 3-stage closing strength adjustment. This allows you to fine-tune the closing speed and force to match your specific needs and door characteristics.

6.1 Adjusting Closing Force

The closing force is adjusted via a screw mechanism located on the main body of the door closer. Refer to the diagram below for the exact location.

  • To Increase Closing Force: Turn the adjustment screw clockwise.
  • To Decrease Closing Force: Turn the adjustment screw counter-clockwise.

Test the door's closing action after each adjustment to achieve the desired speed and force. Avoid over-tightening or loosening the screw excessively.

클로즈업 view of the ABUS 3632 Door Closer TS40 AL, highlighting the adjustment mechanism for closing force.

Figure 4: Detail of the ABUS 3632 Door Closer, showing the adjustment point.

7. 유지관리

Regular maintenance ensures the longevity and optimal performance of your ABUS door closer.

  • 청소: Wipe the door closer periodically with a soft, damp 먼지와 오물을 닦아낼 때는 천을 사용하십시오. 연마성 세제나 용제는 사용하지 마십시오.
  • 매끄럽게 하기: The internal mechanism is factory-lubricated and generally does not require additional lubrication. If squeaking or stiffness occurs, consult a professional.
  • 패스너 점검: Periodically check all mounting screws and fasteners to ensure they are tight. Re-tighten if necessary to prevent loosening over time.
  • 기능 확인: Regularly test the door closer's operation to ensure the door closes smoothly and at the desired speed. Adjust the closing force if needed.

8. 문제 해결

문제 가능한 원인 해결책
문이 완전히 닫히지 않습니다. Closing force is too low. Obstruction in door path. Increase closing force (refer to Section 6.1). Check for and remove any obstructions.
Door closes too quickly/slams. Closing force is too high. Decrease closing force (refer to Section 6.1).
Door closer is noisy. Loose fasteners. Internal mechanism issue. Check and tighten all mounting screws. If noise persists, contact ABUS support.
Door closer feels stiff or inconsistent. Lack of lubrication (rare). Damage to internal components. Ensure no external debris is affecting movement. If issues persist, contact ABUS support.

9. 보증 및 지원

ABUS 제품은 높은 품질 기준에 따라 제조됩니다. 구체적인 보증 정보는 구매 시 동봉된 보증 카드를 참조하거나 ABUS 공식 웹사이트를 방문하십시오. website. If you encounter any issues not covered in this manual or require further assistance, please contact ABUS customer support.

ABUS 공식 Web대지: www.abus.com

© 2026 ABUS. 모든 권리 보유.