Intermatic R8806P101C

Intermatic R8806P101C Sprinkler Irrigation Timer User Manual

Model: R8806P101C | Brand: Intermatic

1. 서론

This manual provides instructions for the installation, operation, and maintenance of the Intermatic R8806P101C Sprinkler Irrigation Timer. This mechanical timer is designed for outdoor use with indexing irrigation valve systems, offering precise control over water usage.

The R8806P101C features a NEMA 3R Raintight Plastic housing, making it suitable for various outdoor environments. It operates at 208/277 Volts with an amp25의 시대 Amps per pole (DPST switch type) and has a 2HP rating. The timer allows for up to 60 ON/OFF set points every 24 hours, providing flexible scheduling for your irrigation needs.

2. 안전 정보

CAUTION - RISK OF ELECTRIC SHOCK

Turn power OFF at the main panel before servicing this switch or the equipment it controls. Connect only copper conductors to switch terminals. This insulator must be replaced after wiring to prevent shock. Keep case locked at all times.

PRECAUCIÓN: RIESGO DE SACUDIDA ELÉCTRICA

Desconecte la corriente en el panel principal antes de revisar el interruptor o el equipo que este controla. Conecte solamente los conductores de cobre a los terminales del interruptor. Este aislador deberá sustituirse luego de finalizar el cableado para evitar posibles sacudidas. Mantenga la cubierta cerrada en todo momento.

3. 설정 및 설치

The Intermatic R8806P101C timer is designed for easy installation. Ensure all local electrical codes are followed during installation. This timer is intended for use with indexing irrigation valve systems only.

3.1 타이머 설치

Mount the timer securely in a location that allows for easy access and visibility. The NEMA 3R Raintight Plastic housing provides protection against outdoor elements.

3.2 전기 연결

Before making any electrical connections, ensure the power supply is turned OFF at the main circuit breaker. The timer requires a 208/277 VAC power source and is rated for 25 Amps per pole (DPST switch type). Connect only copper conductors to the switch terminals.

Intermatic R8806P101C timer with open enclosure showing internal wiring
그림 1: 내부 view of the R8806P101C timer with wiring connections. Ensure power is off before connecting wires.
앞쪽 view of the Intermatic R8806P101C timer inside its gray enclosure
그림 2: 전면 view of the R8806P101C timer mechanism within its protective housing.

4. 사용 설명서

The R8806P101C timer offers flexible scheduling options for your irrigation system.

4.1 현재 시간 설정

Rotate the dial clockwise until the current time aligns with the 'TIME' arrow indicator. Ensure AM/PM is correctly set (the dial typically indicates 'NITE' for PM hours).

A hand adjusting the yellow timer dial on the Intermatic R8806P101C
Figure 3: Adjusting the timer dial to set the current time.

4.2 켜짐/꺼짐 주기 프로그래밍

The timer supports up to 44 ON/OFF operations every 24 hours. Use the included trippers to set your desired watering schedule. Each tripper represents an ON or OFF event.

  • 온 트리퍼스: These activate the irrigation system.
  • OFF Trippers: These deactivate the irrigation system.

Watering increments can be set from 12 minutes to 20 hours and 45 minutes. Additional trippers and pins are sold separately if more cycles are needed.

Close-up of the timer's pin mechanism for setting irrigation schedules
Figure 4: Detail of the timer's pin mechanism for setting ON/OFF cycles.

4.3 Skipper Options

The timer supports up to 14-day skipper options for tailored irrigation, allowing you to skip watering on specific days.

4.4 수동 오버라이드 스위치

An on/off/automatic switch allows for manual control. Use this to temporarily shut down the system during rainy days or to extend watering during dry spells without altering your programmed schedule.

4.5 Rain Sensor Compatibility

The timer is compatible with rain sensors (sold separately). Integrating a rain sensor ensures automatic rain-triggered control, enhancing water conservation by preventing unnecessary watering during rainfall.

Video 1: Official Intermatic video demonstrating the operation of an irrigation timer. This video shows how to set the time and program watering cycles using the dial and trippers.

5. 유지관리

The Intermatic R8806P101C timer requires minimal maintenance. Periodically inspect the enclosure for any damage or signs of wear. Ensure the housing remains securely closed to maintain its raintight integrity.

Keep the internal components free from dust and debris. If cleaning is necessary, ensure the power is disconnected at the main panel and use a dry, soft cloth. Do not use liquid cleaners directly on the timer's mechanism.

6. 문제 해결

If your Intermatic R8806P101C timer is not functioning as expected, consider the following common issues:

  • Timer not running: Check the power supply at the main circuit breaker. Ensure all electrical connections are secure.
  • Irrigation not turning ON/OFF at scheduled times: Verify that the ON and OFF trippers are correctly positioned on the dial. Ensure the current time is accurately set. Check the manual override switch is in the 'automatic' position.
  • 불규칙적인 물주기: Ensure the trippers are firmly attached and have not shifted. If a rain sensor is connected, check its functionality and ensure it is not preventing watering unnecessarily.

문제가 지속될 경우 자격을 갖춘 전기 기술자에게 문의하거나 Intermatic 고객 지원팀에 연락하십시오.

7. 사양

특징사양
모델 번호R8806P101C
상표인터매틱
권tage208 / 277 VAC
Amp에라 지25 Amp극당 s
HP 등급2마력
스위치 유형DPST
주택NEMA 3R Raintight Plastic
세트 포인트Up to 60 ON/OFF per 24 hours
Watering Increments12분 ~ 20시간 45분
Skipper OptionsUp to 14-day
치수(D x W x H)3.75인치 x 5.5인치 x 9.38인치
품목 무게2.8파운드
인증CSA Listed Certified

8. 보증 및 지원

For warranty information and customer support, please refer to the official Intermatic web해당 사이트를 방문하거나 고객 서비스 부서에 문의하세요. 보증 청구를 위해 구매 영수증을 보관하세요.

Intermatic 연락처 정보:

  • Web대지: www.intermatic.com
  • Refer to product packaging or the official website for specific contact numbers and support hours.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.