Robertshaw 700-506 Gas Valve Instruction Manual

모델 : 700-506

1. 제품 오버view

The Robertshaw 700 series gas valve uni-kits are designed for use in intermittent pilot, direct spark, and hot surface ignition applications. This model, the 700-506, is a fast-opening gas valve with a capacity of up to 200,000 BTUH.

It integrates a manual valve, a pilot valve, and a main gas pressure regulator into a single unit. These valves are suitable for various residential and commercial heating systems, including central heating units, wall heaters, boilers, and mobile home furnaces.

주요 특징은 다음과 같습니다.

  • Normally closed solenoid for safety.
  • Compact size with high flow rates.
  • Standard NEMA terminals for electrical connections.
  • Inlet filtered screen to prevent debris entry.
  • Compatibility with various gas types: natural, manufactured, mixed, LP, and LP/air mixtures.
Robertshaw 700-506 가스 밸브

Image 1.1: Robertshaw 700-506 Gas Valve. This image displays the main unit of the gas valve, highlighting its compact design and connection points.

2. 안전 정보

경고: 부적절한 설치, 조정, 개조, 서비스 또는 유지보수는 재산 피해, 인명 피해 또는 사망을 초래할 수 있습니다. 본 장비를 설치하거나 서비스하기 전에 설치, 작동 및 유지보수 지침을 꼼꼼히 읽으십시오.

  • 설치 및 서비스는 자격을 갖춘 설치자, 서비스 기관 또는 가스 공급업체를 통해 수행되어야 합니다.
  • Always shut off the main gas supply before attempting any installation, service, or maintenance.
  • Check for gas leaks after any service or installation using a soap solution; never use an open flame.
  • 작동 중 적절한 환기를 보장하십시오.
  • 우회하거나 t하지 마십시오amp어 안전 장치와 함께.

This manual provides general guidelines. Always refer to the specific appliance manufacturer's instructions and local codes for complete safety and installation procedures.

3. 패키지 내용

패키지를 열면 모든 구성품이 들어 있는지 확인하세요.

  • Robertshaw 700-506 Gas Valve Unit
  • Product & Instructions Guide (this document and supplementary materials)
  • Necessary parts for conversion to direct spark or hot surface applications (as specified in the included guide).

4. 사양

사양 세부 사항
모델 번호 700-506
재료 금속
외부 마감 스테인리스 스틸
색상
품목 치수(L x W x H) 3 x 3 x 4.13 인치
품목 무게 2파운드
입구 연결 크기 0.5 인치
입구 연결 유형 기준
콘센트 연결 크기 3 인치
포트 수 1
커넥터 유형 플랜지
사양 충족 ASME, CSA, UL
Gas Types Supported Natural, Manufactured, Mixed, LP, LP/Air mixtures

5. 설치 및 설정

중요한: Installation of this gas valve must be performed by a qualified and licensed professional in accordance with all local and national codes and regulations.

  1. 준비:
    • Ensure the main gas supply to the appliance is turned off.
    • Disconnect electrical power to the appliance.
    • 해당 구역을 철저히 환기하세요.
  2. Removal of Old Valve (if applicable):
    • Carefully disconnect gas lines and electrical wiring from the existing valve.
    • Remove the old valve, taking note of its orientation and connections.
  3. Mounting the New Valve:
    • Mount the Robertshaw 700-506 gas valve in the same orientation as the original valve, ensuring it is securely fastened.
    • The valve is designed with easily accessible wiring connections, manual selector, and adjustments.
  4. Gas Line Connections:
    • Connect the gas supply lines to the inlet and outlet ports of the new valve. Use appropriate pipe sealant on all threaded connections.
    • The inlet connection size is 0.5 inches, and the outlet connection size is 3 inches. Ensure compatible fittings are used.
  5. 전기 배선:
    • Connect the electrical wiring to the standard NEMA terminals on the valve according to the appliance manufacturer's wiring diagram.
  6. 누출 테스트:
    • 주 가스 공급 장치를 천천히 켭니다.
    • Apply a soap solution to all gas connections. Bubbles indicate a leak. If a leak is detected, turn off the gas supply immediately and tighten connections until no bubbles appear.
    • 가스 누출을 확인하기 위해 화염을 사용하지 마십시오.
  7. Initial Startup and Adjustment:
    • Refer to the appliance manufacturer's instructions for specific startup procedures and pilot light ignition.
    • Adjust the main gas pressure regulator as needed, following the appliance specifications.

This uni-kit includes all necessary parts and instructions for conversion to direct spark or hot surface applications. Consult the supplementary instructions guide for detailed conversion procedures.

6. 운영

The Robertshaw 700-506 gas valve operates in conjunction with your heating appliance's control system to regulate gas flow to the main burner and pilot light.

  • Manual Valve: This allows for manual shut-off of the gas supply to the entire valve. Ensure it is in the "ON" position for normal operation.
  • Pilot Valve: Controls the gas flow to the pilot light. For systems with standing pilots, this valve must be open for the pilot to ignite and remain lit. For intermittent pilot or direct spark systems, the pilot valve opens as part of the ignition sequence.
  • Main Gas Pressure Regulator: Maintains a consistent gas pressure to the main burner for efficient combustion.
  • Fast Opening Feature: This valve is designed for quick response, allowing for rapid gas flow when called for by the thermostat or control system.

Always follow the operating instructions provided by the manufacturer of your specific heating appliance for proper startup, shutdown, and general use.

7. 유지관리

Regular maintenance helps ensure the safe and efficient operation of your gas valve and heating system. All maintenance should be performed by a qualified service technician.

  • 연례 검사: Have a qualified technician inspect the gas valve and entire heating system annually. This includes checking for leaks, proper gas pressure, and overall valve function.
  • Inlet Filtered Screen: The valve features an inlet filtered screen. During annual inspections, this screen should be checked for any debris or blockages and cleaned if necessary to maintain proper gas flow.
  • 청소: Keep the exterior of the valve clean and free from dust and debris. Do not use harsh chemicals or abrasive cleaners.

Do not attempt to disassemble or repair the gas valve yourself. Contact a qualified service professional for any issues beyond routine cleaning and inspection.

8. 문제 해결

If you experience issues with your heating appliance, consider the following common troubleshooting steps. For safety, always contact a qualified technician for diagnosis and repair if you are unsure or suspect a gas leak.

  • No Heat / Burner Not Igniting:
    • Check if the main gas supply is turned on.
    • Verify that the manual valve on the 700-506 is in the "ON" position.
    • Ensure electrical power to the appliance is active.
    • 온도 조절기 설정을 확인하십시오.
    • Inspect the pilot light (if applicable). If it's out, follow your appliance's instructions for relighting.
  • Pilot Light Not Staying Lit:
    • This can indicate an issue with the thermocouple/thermopile or the pilot assembly.
    • Ensure the pilot flame is strong and consistently engulfing the thermocouple/thermopile.
    • A qualified technician should inspect and replace faulty components.
  • 가스 냄새:
    • If you smell gas, immediately turn off the main gas supply, open windows and doors, evacuate the premises, and call your gas company or a qualified technician from a safe location.
    • Do not operate any electrical switches or phones inside the building.

9. 가스 종류 변환

The Robertshaw 700-506 gas valve is compatible with various gas types. However, specific conversion kits are required to switch between natural gas and LP gas.

  • To convert the valve for use with 천연가스, use Robertshaw conversion kit 1751-003.
  • To convert the valve for use with LP 가스, use Robertshaw conversion kit 1751-013.

경고: Gas type conversion must only be performed by a qualified service technician. Incorrect conversion can lead to unsafe operation, property damage, personal injury, or loss of life.

10. 보증 및 지원

For information regarding the product warranty, please refer to the warranty documentation included with your purchase or visit the official Robertshaw website. For technical support, replacement parts, or service inquiries, please contact Robertshaw customer service or a qualified service professional.

자세한 정보와 연락처는 다음에서 확인할 수 있습니다. Robertshaw Store on Amazon 또는 공식 회사 web대지.

© 2026 Robertshaw. 모든 권리 보유. 정보는 예고 없이 변경될 수 있습니다.

관련 문서 - 700-506

사전view Robertshaw HVACR 난방 카탈로그: 온도 조절 장치, 가스 밸브 및 구성 요소
Comprehensive catalog from Robertshaw detailing HVACR heating components, including Pro-Series wall thermostats, various gas valves (millivolt, 24V, universal), ignitors, pilots, and accessories. Find product specifications, model numbers, and cross-references for professional installation and replacement.
사전view 로버트쇼 가스 밸브 교차 참조 가이드
수천 개 부품에 대한 교차 참조 도구를 포함한 Robertshaw 가스 밸브에 대한 종합 가이드입니다. 이 문서는 수동, 유압, 24V 복합, 2-S 등 다양한 모델을 자세히 설명합니다.tage, 횡격막, 라인 볼륨tage 및 밀리볼트 가스 밸브에 대한 사양, 모델 번호 및 응용 프로그램을 제공합니다.
사전view Robertshaw 720 시리즈 듀얼 밸브 가스 난방 제어 장치 설치 데이터
로버트쇼 720 시리즈 컨버터블/스텝 개방형 듀얼 밸브 가스 난방 제어 장치에 대한 설치 및 서비스 지침으로, 사양, 배선, 작동 및 문제 해결 방법이 포함되어 있습니다.
사전view Robertshaw 글로벌 제품 카탈로그: HVACR, 조리 및 냉장 제어
랜코, 파라곤, 브레이번, 메르센 등 믿을 수 있는 브랜드의 다양한 HVACR, 조리 및 냉장 제어 제품을 선보이는 포괄적인 로버트쇼 글로벌 제품 카탈로그를 살펴보세요. 상업 및 주거용 온도 조절 장치, 가스 밸브, 타이머, 점화 장치 등을 살펴보세요.
사전view Robertshaw 2374 시리즈 공기압 감지 스위치
공압식, 공기압 감지 및 수동 리셋 모델을 갖춘 Robertshaw 2374 시리즈 공기압 감지 스위치를 살펴보세요. 이 문서에서는 각 스위치의 용도, 기능, 이점을 자세히 설명하고 다양한 제조업체의 교체 부품에 대한 포괄적인 상호 참조 가이드를 제공합니다.
사전view Robertshaw Ranco Reversing Valves Installation Guide
Installation and application guide for Robertshaw Ranco Reversing Valves and 4-Way Pilot Valves. Includes specifications, part numbers, and installation procedures.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.