Empire VFSR24LP

Empire Vent-Free Slope Glaze Burner VFSR24LP Instruction Manual

Model: VFSR24LP

1. 서론

This manual provides essential information for the safe installation, operation, and maintenance of your Empire Vent-Free Slope Glaze Burner, Model VFSR24LP. This 24-inch propane burner features a Millivolt Safety Valve with an on/off switch and is designed for use with Empire "LS" log sets of the same size. It incorporates internal ceramic beads to enhance flame appearance and can produce up to 38,000 BTU.

2. 중요한 안전 정보

Read this entire manual carefully before installation and use of this vent-free gas burner. Failure to follow these instructions could result in property damage, personal injury, or loss of life.

  • 전문적인 설치: 설치 및 서비스는 자격을 갖춘 설치자, 서비스 기관 또는 가스 공급업체를 통해 수행되어야 합니다.
  • Vent-Free Appliance: This is a vent-free appliance. It obtains combustion air from the room in which it is installed. Adequate ventilation must be provided.
  • 연료 유형: This burner is designed for use with Propane (LP) gas only. Do not use any other fuel.
  • 정리 : Maintain proper clearances to combustibles as specified in the installation instructions.
  • 일산화탄소: Vent-free gas products produce carbon monoxide. Ensure proper room size and ventilation. Install a carbon monoxide detector in your home.
  • 뜨거운 표면: The burner and surrounding surfaces will become hot during operation. Keep children, pets, and clothing away.

3. 설정 및 설치

3.1 Fireplace Requirements

Ensure your fireplace meets the minimum dimensions required for the 24-inch burner and associated log set. Refer to the diagram and table below for guidance.

Fireplace Dimensions Diagram and Table

이미지 설명: A diagram illustrating fireplace dimensions (front width opening, rear width, depth, and height) with a table below it. The table provides non-Empire minimum firebox dimensions for various Slope Glaze Burner models, including log length, BTU input, front width, rear width, depth, height, and shipping weight. For the VFSR-24 model, it specifies a 24-inch log length, 36,000 BTU input, 34-inch front width, 27-inch rear width, 14-inch depth, and 18-inch height.

3.2 Fuel Type Connection

This burner operates on Propane (LP) gas. Ensure your gas supply is correctly connected by a qualified professional.

Propane Gas Symbol

이미지 설명: A circular grey icon with a white silhouette of a propane tank and the word "PROPANE" in white text below it, indicating the required fuel type.

3.3 Millivolt Wiring

The burner features a Millivolt Safety Valve. Refer to the wiring diagram for proper electrical connections, especially if installing an optional thermostat or remote control receiver.

Millivolt Wiring Diagram

이미지 설명: A detailed wiring diagram titled "MILLIVOLT WIRING". It shows connections for a gas valve, thermopile, thermocouple, and optional components like a thermostat, wall switch, and remote control receiver. Wires are color-coded (red, green, black) and labeled with their functions. A note indicates that any original wire supplied with the unit must be replaced with number 18, 150°C wire or its equivalent if damaged.

3.4 Log Set Placement

This burner requires an Empire "LS" log set of the same size (24-inch) for optimal performance and appearance. Follow the log set manufacturer's instructions for proper placement on the burner.

4. 사용 설명서

4.1 Pilot Ignition (Standing Pilot/Piezo)

  1. 기기에 가스가 공급되고 있는지 확인하십시오.
  2. Locate the control knob on the Millivolt Safety Valve.
  3. Push the control knob in and turn it to the "PILOT" position.
  4. While holding the knob in, repeatedly press the piezo igniter button until the pilot flame ignites.
  5. Continue to hold the control knob in for approximately 30-60 seconds after the pilot ignites to allow the thermocouple to heat up. Release the knob; the pilot should remain lit. If it extinguishes, repeat steps 3-5.

4.2 버너 작동

  1. Once the pilot is lit, turn the control knob from "PILOT" to the "ON" position.
  2. Use the integrated on/off switch on the Millivolt Safety Valve to turn the main burner on or off.
  3. If a remote control or wall switch is installed, use that device to control the main burner.

4.3 Shutting Down the Burner

  1. Turn the main burner off using the on/off switch or remote control.
  2. To turn off the pilot, turn the control knob to the "OFF" position.
  3. For extended periods of non-use, turn off the main gas supply to the appliance.

5. 유지관리

Regular maintenance ensures safe and efficient operation of your burner.

  • 연례 검사: Have the burner and gas connections inspected annually by a qualified service technician.
  • 청소: Keep the burner and log set free of dust and debris. Use a soft brush or vacuum cleaner. Do not use abrasive cleaners.
  • Pilot and Burner Ports: Periodically check pilot and burner ports for obstructions. Clean gently if necessary.
  • 로그 세트: Inspect the log set for cracks or damage. Replace any damaged logs.

6. 문제 해결

If you experience issues, consult this section before calling for service.

문제가능한 원인해결책
파일럿이 켜지지 않습니다가스 공급 없음
파일럿 오리피스가 막혔습니다
점화 장치가 불꽃을 일으키지 않음
Check gas valve
Clean pilot orifice
Check igniter electrode gap
Pilot lights but will not stay litThermocouple not heating
느슨한 열전대 연결
Hold pilot knob longer
Tighten thermocouple connection
메인 버너가 켜지지 않습니다Pilot not lit
Control knob not in "ON" position
On/off switch off
라이트 파일럿
Turn control knob to "ON"
스위치 켜기
Burner produces yellow flame/soot막힌 버너 포트
잘못된 가스 압력
버너 포트 청소
자격을 갖춘 기술자에게 문의

7. 사양

특징세부 사항
모델VFSR24LP
상표제국
버너 크기24인치
연료 유형프로판(LP)
BTU Input (Max)38,000비티유
밸브 유형Millivolt with On/Off Switch
Pilot TypeStanding Pilot/Piezo Ignition
Log Set RequirementEmpire "LS" log sets of the same size
재료Ceramic (internal beads)
제품 치수28.5인치 깊이 x 16.75인치 너비 x 9인치 높이
품목 무게27 파운드
한국어:720968265609

8. 보증 및 지원

For warranty information and technical support, please refer to the documentation provided with your product or contact Empire customer service directly. Keep your purchase receipt for warranty claims.

© 2026 Empire. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.